دوره 6، شماره 2 - ( 3-1396 )                   | برگشت به فهرست نسخه ها


XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Elhamamsy A R, El Sharkawy M S, Zanaty A F, Mahrous M A, Ezzat Mohamed A, Abushaaban E A. Circulating miR-92a, miR-143 and miR-342 in Plasma are Novel Potential Biomarkers for Acute Myeloid Leukemia. Int J Mol Cell Med 2017; 6 (2) :77-86
URL: http://ijmcmed.org/article-1-636-fa.html
Circulating miR-92a, miR-143 and miR-342 in Plasma are Novel Potential Biomarkers for Acute Myeloid Leukemia. مجله بین المللی سلولی و مولکولی. 1396; 6 (2) :77-86

URL: http://ijmcmed.org/article-1-636-fa.html


:   (8876 مشاهده)

MicroRNAs (miRNAs) are small non-coding RNAs that function as post-transcriptional gene expression regulators. The expression profiling of miRNAs has already entered into cancer clinics as diagnostic and prognostic biomarkers to assess tumor initiation, progression and response to treatment in cancer patients. Recent Studies opened the way for the use of circulating miRNAs as non-invasive diagnosis and prognosis of Acute Myeloid Leukemia (AML). The aim of this study was to identify plasma miR-92a, miR-143 and miR-342 expression signatures in AML patients to introduce new markers for establishing AML diagnosis and prognosis. Blood samples were collected from 65 AML patients and 50 controls. The expression of three target miRNAs (miR-92a, miR-143 and miR-342) was measured using quantitative real-time PCR method. Plasma levels of miR-92a, miR-143 and miR-342 were significantly lower in AML patients in comparison with control group. Receiver operator characteristic (ROC) analysis revealed that the sensitivity and specificity values of miR-92a were 81.5% and 94%, respectively, with a cut-off value of 0.704. The sensitivity and specificity values of miR-143 were 87.7% and 80%, respectively, with a cut-off value of 0.65. The sensitivity and specificity values of miR-342 were 75.4% and 90%, respectively, with a cut-off value of 0.479. Our findings suggest that plasma miR-92a, miR-143 and miR-342 could be promising novel circulating biomarkers in clinical detection of AML.

متن کامل [PDF 577 kb]   (3286 دریافت)    
نوع مطالعه: Original Article | موضوع مقاله: Biomarkers (diagnosis & treatment)
دریافت: 1395/10/10 | پذیرش: 1395/12/9 | انتشار: 1396/3/10

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به International Journal of Molecular and Cellular Medicine IJMCM می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | International Journal of Molecular and Cellular Medicine IJMCM

Designed & Developed by : Yektaweb